Part NoDescription
QL-261-100eVHP High Pressure Vessel
  • Vessel volume 100 mL.
  • Recommended usable volume 12-50 mL, depending on sample.
  • Maximum operating temperature 260 °C.
  • Normal operating temperature 230 °C.
  • Design pressure ~165 bar/ 2400 psi.
  • Maximum pressure ~83 bar/ 1200 psi.
  • Operating pressure control at ~42 bar/ 610 psi (Op Guard limit).
  • Every vessel is monitored individually for temperature and pressure.
  • Vessel over-pressure management system has controlled release of over pressure for full operational temperature range.
  • Each vessel is individually tested for 600 psi (40 bar) pressure.
  • Equipped with resealing OPGuard™ vessel protection system.
QL-260-150Carousel, 18-eVHP, for QWave 2000
• Total 18 eVHP vessels.
• Min recommended vessels used – 4.
• Capable of digesting samples in groups of 4, 6, 8, 12 and 18.
QL-261-130Carousel, 12-eVHP, for QWave 1000
• Total 12 eVHP vessels.
• Min recommended vessels used – 4.
• Capable of digesting samples in groups of 4, 6, 8, and 12
QL-261-158eVHP Vessel Wrench
QL-261-159PRV Wrench
QL-261-150eVHP Vessel handling station
QL-262-1726 eVHP Vessel Carrying Tray
QL-262-100LVHT High Throughput Vessel
  • Vessel volume 50 mL.
  • Min recommended vessels to used – 6.
  • Recommended usable volume 10-25 mL, depending on sample.
  • Maximum operating temperature 260°C.
  • Normal operating temperature 180°C.
  • Design pressure ~62 bar/ 900 psi.
  • Maximum pressure ~42 bar/ 600 psi.
  • Operating pressure control at ~18 bar/ 250 psi (Op Guard limit).
  • Every vessel is monitored individually for temperature and pressure.
  • Vessel over-pressure management system has controlled release of over pressure for full operational temperature range.
  • Each vessel is individually tested for 250 psi (18 bar) pressure.
  • Equipped with resealing OPGuard™ vessel protection system.
QL-260-250Carousel, 36-LVHT, for QWave 2000
• Total 36 eVHP vessels.
• Min recommended vessels used – 6.
• Capable of digesting samples in groups of 6, 9, 18, 27, and 36
QL-260-260Carousel, 24-LVHT, for QWave 1000
• Total 24 eVHP vessels.
• Min recommended vessels used – 6.
• Capable of digesting samples in LVHT vessel in group of 6, 9, 18 and 24.
QL-262-158LVHT Vessel Wrench
QL-261-159PRV Wrench
QL-262-150LVHT Vessel handling station
QL-262-17312 LVHT Vessel Carrying Tray
QL-261-107eVHP Vessel Liner, TFM
QL-261- 101eVHP / LVHT Over Pressure Release Valve
QL-262-104LVHT Vessel Bottom, TFM
QL-101-501QWave / QLAB controller module with powerful & friendly user interface
QL-265-111

In-situ Pressure Monitoring Vessel.

  • Replacement vessel.
  • Requires onboard electronics.
  • Requires wiring harnesses.
  • Requires monitoring software integration.
QL-265-121

In-situ Temperature Monitoring Vessel.

  • Replacement vessel.
  • Requires onboard electronics.
  • Requires wiring harnesses.
Requires monitoring software integration